网站到期及时续费



时代中广传媒科技--专业网络服务提供商
域名注册 虚拟主机 企业邮箱
网站建设 云服务器 云 主 机
E_mail:info@vpsdns.com.cn
http://west.vpsdns.com.cn
QQ:18890518
微信:13261210013
电话:010-81898888 13261210013
域名注册/虚拟主机/企业邮箱/网站建设/香港主机/美国主机/云主机/微信小程序
香港主机、美国主机—无需备案的主机、不用备案主机,免备案主机 
虚拟主机:(独立IP 双线空间)  更稳定速度更快
企业邮箱:六线机房\大附件\大容量\电子传真\全球邮件转发\任意邮件监控\高级防垃圾反病毒网关\短信功能.
 

网站开发作品:
河北金德古建 http://www.hdllw.com
齿博士医疗 http://www.chiboshi.cn/
航天国际影视 http://www.htgjys.com/
海波民俗度假村http://www.beijingminsu.cn
晶客博雅营销 http://www.jing-club.com/
晶客博雅策划 http://www.jingparty.com/
博睿智科技 http://www.cnbrz.com
稳捷特广告 http://www.winage.com.cn
北京奥文创赢 http://www.cawcy.com
时代中广传媒科技--专业网络服务提供商
域名注册 虚拟主机 企业邮箱
网站建设 云服务器 云 主 机
E_mail:info@vpsdns.com.cn
http://west.vpsdns.com.cn
QQ:836237803
电话:010-81898888 13261210013
香港主机、美国主机—无需备案的主机、不用备案主机,免备案主机
北京网站建设_回龙观网站建设
MSN MSN MSN MSN     
Position:Home > Technology >

How Ultrasonic Flowmeters Work

Ultrasonic flowmeters use sound waves to determine the velocity of a fluid flowing in a pipe. At no flow conditions, the frequencies of an ultrasonic wave transmitted into a pipe and its reflections from the fluid are the same. Under flowing conditions, the frequency of the reflected wave is different due to the Doppler effect. When the fluid moves faster, the frequency shift increases linearly. The transmitter processes signals from the transmitted wave and its reflections to determine the flow rate.

Transit time ultrasonic flowmeters send and receive ultrasonic waves between transducers in both the upstream and downstream directions in the pipe. At no flow conditions, it takes the same time to travel upstream and downstream between the transducers. Under flowing conditions, the upstream wave will travel slower and take more time than the (faster) downstream wave. When the fluid moves faster, the difference between the upstream and downstream times increases. The transmitter processes upstream and downstream times to determine the flow rate.

Transit time ultrasonic flowmeters are usually more accurate than Doppler ultrasonic flowmeters. Doppler ultrasonic flowmeters are usually more economical.

How to Use Ultrasonic Flowmeters

Ultrasonic flowmeters are commonly applied to measure the velocity of liquids that allow ultrasonic waves to pass, such as water, molten sulfur, cryogenic liquids, and chemicals. Transit time designs are also available to measure gas and vapor flow. Be careful because fluids that do not pass ultrasonic energy, such as many types of slurry, limit the penetration of ultrasonic waves into the fluid. In Doppler ultrasonic flowmeters, opaque fluids can limit ultrasonic wave penetration to near the pipe wall, which can degrade accuracy and/or cause the flowmeter to fail to measure. Transit time ultrasonic flowmeters can fail to operate when an opaque fluid weakens the ultrasonic wave to such an extent that the wave does not reach the receiver.

Ultrasonic flowmeters do not obstruct flow so they can be applied to sanitary, corrosive and abrasive liquids. Some ultrasonic flowmeters use clamp-on transducers that can be mounted external to the pipe and do not have any wettedparts. Temporary flow measurements can be made using portable ultrasonic flowmeters with clamp-on transducers. Clamp-on transducers are especially useful when piping cannot be disturbed, such as in power and nuclear industry applications. In addition, clamp-on transducers can be used to measure flow without regard to materials of construction, corrosion, and abrasion issues. However attractive, the use of clamp-on transducers introduces additional ultrasonic interfaces that can affect the reliability and performance of these flowmeters. In particular, if not properly applied and maintained, attenuation of the ultrasonic signal can occur at the interfaces between the clamp-on transducers and the outside pipe walls, and between the inside pipe walls and the fluid.

Ultrasonic flowmeters are available in sizes to 72 inches and larger.

Application Cautions for Ultrasonic Flowmeters

For transit time ultrasonic flowmeters, be sure that the fluid can adequately conduct ultrasonic waves, because the flowmeter will not measure when the ultrasonic waves cannot penetrate the flow stream between the transducers. Similarly, ultrasonic waves must be able to penetrate the fluid for Doppler flowmeters to operate accurately. When the fluid is relatively opaque and does not penetrate the fluid, Doppler flowmeters tend to measure the velocity of the fluid at or near the pipe wall, which can cause significant measurement error and/or cause the flowmeter to fail.

For Doppler ultrasonic flowmeters, be sure that the fluid adequately reflects ultrasonic waves, because the flowmeter will not operate without a reflected ultrasonic signal. Depending upon design, reflections can occur due to small bubbles of gas in the flow stream or the presence of eddies in the flow stream. If not already present in the flowing stream, generating these sources of reflection can be difficult in practice. Fortunately, some combination of bubbles of gas and/or eddies are present in most applications.

The velocity of the solid particles in slurry can be different than its liquid carrier fluid. Be careful applying ultrasonic technology when the solid particles can become concentrated in one part of the flowing stream, such as in a horizontal pipe flowing at a relatively low velocity. Be careful when applying Doppler ultrasonic flowmeters in slurry applications because the solid particles can produce strong signals that can cause the Doppler flowmeter to measure the velocity of the solids and not the velocity of the liquid.

Avoid fluids that can coat wetted transducers or coat the pipe wall in front of non-wetted transducers, because the flowmeter will not measure when the ultrasonic waves cannot enter the flow stream. Be sure to maintain reliable clamp-on transducer connections to the pipe wall, because the flowmeter will not measure when the ultrasonic waves are not able to reach the fluid.

Be sure to understand the process and apply these flowmeters properly. For example, a periodic cleaning process upstream may cause the flowmeter to stop working because the dirt may not allow ultrasonic energy to pass through the fluid. Further, if the dirt coats wetted transducers, the flowmeter may fail to operate until it is cleaned.